Product details and technical information
Technical Details
Consists of FM 200 extinguishing agent, four main components and their accessories.
- FM-200 Components: Consists of the cylinder storing FM-200 gas, the cylinder guard and the FM 200 discharge nozzle.
- Control Panel: The brain of the system, used to display and monitor detection devices and equipment and activate the system.
- Detection and Alarm Components: The system’s detection devices and accessories, and sounders providing audible and visual warnings, are external components that act as its eyes and ears.
- Auxiliary Equipment: Consists of warning signs, hoses, connection fittings, pressure gauges, or the actuator required to operate the solenoid valve and cylinder valve.
The amount of FM 200 gas required for the protected volume is calculated according to NFPA 12 and TS ISO 14520 standards and rules. An FM 200 cylinder suitable for the required quantity is selected. FM-200 discharge nozzles are installed at the necessary points in the room, which is equipped with a cross-zoned fire detection system. When the smoke detectors activate, the panel energises the FM-200 system’s solenoid valve. All FM 200 gas is discharged into the protected volume within a maximum of 10 seconds.
The system can operate automatically or manually. Depending on the facility’s characteristics and requirements, fixed gaseous suppression systems are designed to comply with the mandatory TS ISO 14520 “Gaseous Fire-Extinguishing Systems — Physical Properties and System Design” and TS EN 15004 “Fixed Firefighting Systems — Gas Extinguishing Systems — Design, Installation and Maintenance” standards.
- Computer and Server Rooms
- Telephone and Telecommunications Rooms
- Electrical dagitim odalari / merkezleri
- Valuable Material Storage Areas
- Laboratories
- Bank Vaults, Archives, Libraries
- Museums and Art Galleries
- FM 200 gas can be used safely in turbine enclosures and similar locations.
FM-200 is the most widely used Halon alternative, introduced after the use of Halon 1301 was banned. Its chemical name is heptafluoropropane. FM 200 extinguishes fires by interrupting chemical reactions and absorbing heat energy. FM 200 gaseous suppression systems are recommended when at least one of the following conditions applies: The value of the protected materials or their importance to business continuity requires a fire system that responds within seconds. A sprinkler system would damage the protected materials. The protected area is occupied. Post-fire cleaning needs to be eliminated. Easy design and installation are required. FM200 Gaseous System Features: A colourless, odourless, electrically non-conductive extinguishing agent. Its ozone depletion potential is zero, and its atmospheric lifetime is 31-42 years. It extinguishes through physical action. It leaves no residue after discharge and requires no cleaning; the gas disperses into the atmosphere. It can be used safely in occupied spaces. It is the most widely used alternative to Halon 1301. It is economical and requires little space. Discharge time is 10 seconds.